Transonic flow over the RAE 2822 airfoil using the CLI
A 2D RANS case run from the command line with a packaged input file; results read in ParaView
This tutorial includes:
- Tutorial features
- Overview of the problem to solve
- Before you begin
- Setting up the working directory
- Reading the case
- Obtaining the solution
- Viewing the results in ParaView
- Further discussion
Tutorial features
This tutorial uses the command-line solver: you read and edit the input file in a text editor, run wake_2d_mixed in a terminal, and open the results in ParaView. Wake CFD Desktop is not used.
In this tutorial you will learn about:
- running a steady 2D compressible RANS case from a single input file,
- the few settings a transonic case needs beyond the solver defaults (a slope limiter, an adaptive CFL),
- stopping a run when the lift and drag have settled instead of after a fixed number of iterations,
- opening the flow field and the airfoil surface in ParaView and plotting the surface pressure against wind-tunnel data.
| Component | Feature | Details |
|---|---|---|
| Interface | Command line | wake_2d_mixed with an input file (deck); --validate before the run |
| Input file | Analysis | 2D, steady |
| Flow model | Navier–Stokes, compressible, Spalart–Allmaras turbulence model | |
| Material | Ideal gas, constant viscosity chosen for the Reynolds number | |
| Boundary conditions | No-slip wall (airfoil), farfield | |
| Numerical method | Density-based solver defaults + Venkatakrishnan–Wang limiter | |
| Run control | Adaptive CFL, monitor-based stop (CL, CD) | |
| Outputs | Volume field, airfoil surface, force history | |
| ParaView | Views | Mesh, Mach number contour |
| Charts | Residual and lift history, surface pressure coefficient against experiment |
Overview of the problem to solve
The RAE 2822 is a supercritical airfoil section. At the conditions of AGARD AR-138 Case 6 the flow over the upper surface accelerates past the speed of sound and returns to subsonic speed through a shock wave at about 55 % of the chord. The case is a standard check for transonic RANS solvers because the shock position depends on the turbulence model, the numerical dissipation and the wall resolution together.
| Quantity | Value |
|---|---|
| Freestream Mach number | 0.729 |
| Angle of attack | 2.31° |
| Reynolds number (chord) | \(6.5 \times 10^{6}\) |
| Freestream pressure, temperature | 101,325 Pa, 288.15 K |
| Chord | 1 m |
The Mach number and angle of attack are the free-air values of the experiment: the wind-tunnel values (Mach 0.725, 2.92°) corrected for the tunnel walls. The surface pressure measured in the tunnel is the reference for this tutorial.
The mesh is the RAE 2822 turbulent mesh distributed with the SU2 test cases: 13,937 nodes, quadrilaterals in the boundary layer and triangles outside, 192 edges on the airfoil, and a circular farfield 100 chords from the airfoil.
Before you begin
You need:
- the Wake CFD 2D solver,
wake_2d_mixed(wake_2d_mixed.exeon Windows) — see Installation; - ParaView 5.10 or later to view the results;
- the tutorial files listed below.
| File | Contents |
|---|---|
rae2822_sa_defaults.jsonc |
The input file (deck) of this tutorial |
_mesh/mesh_RAE2822_turb.su2 |
The mesh, in SU2 format |
rae2822_case6_cp_exp.csv |
Measured surface pressure coefficient, AGARD AR-138 Case 6 (x_c, Cp_exp) |
paraview_cp.py |
Optional: the ParaView steps of the surface-pressure chart as a script |
The files are in the tutorials/rae2822_transonic/ folder of the examples that come with the solver (shared/examples/ in the installation folder).
Setting up the working directory
Wake CFD writes its results next to the input file, so run the tutorial in a copy and keep the installed examples unchanged.
- Copy the whole
rae2822_transonicfolder to a working location, for example~/wake-work/rae2822_transonic. Keep_mesh/inside it: the deck refers to the mesh by a relative path. - Open a terminal in that folder.
Reading the case
Open rae2822_sa_defaults.jsonc in a text editor. A deck is JSON with comments (//); each top-level block describes one part of the problem. This deck writes down the physics of the case and leaves almost every numerical setting at its default. The blocks are described below in the order they appear in the file.
Analysis and mesh
"analysis": { "time": "steady", "dimension": 2 },
"mesh": [
{ "file_name": "_mesh/mesh_RAE2822_turb.su2", "format": "su2" }
],time: steadyasks for a steady-state solution;dimension: 2means the case is run with the 2D solver.file_nameis relative to the folder of the deck.- The mesh has two boundary markers,
AIRFOILandFARFIELD. The boundary conditions refer to them by these names.
Flow model and material
"models": {
"type": "navier_stokes",
"regime": "compressible",
"turbulence": { "model": "sa" }
},
"materials": [
{
"name": "Air", "type": "pure",
"eos": { "type": "ideal_gas", "gas_constant": 287.87 },
"viscosity": { "type": "constant", "value": 4.6686e-5 },
"conductivity": { "type": "constant_prandtl", "prandtl": 0.72 }
}
],navier_stokeswithcompressibleselects the viscous density-based solver;sais the Spalart–Allmaras turbulence model.- The ideal gas uses γ = 1.4 by default.
- The viscosity is constant and chosen so that the Reynolds number matches the experiment: ρ = p / (R T) = 1.2215 kg/m³, U = 0.729 a = 248.43 m/s, μ = ρ U c / Re = \(4.6686 \times 10^{-5}\) Pa·s.
Reference values
"reference": {
"density": 1.221523, "pressure": 101325.0,
"temperature": 288.15, "velocity": 248.4272,
"area": 1.0, "length_moment": [1.0, 1.0, 1.0],
"origin_moment": [0.25, 0.0, 0.0]
},Force coefficients and PressureCoefficient are normalized with q = ½ ρ U² of these values, the reference area (1 m² per unit span) and, for the moment, the reference length and the quarter-chord point.
Boundary conditions
"domains": [
{
"name": "fluid", "type": "fluid", "material": "Air",
"boundaries": [
{ "name": "airfoil", "type": "wall",
"momentum": "no_slip", "mesh_markers": ["AIRFOIL"] },
{ "name": "farfield", "type": "farfield",
"mesh_markers": ["FARFIELD"],
"mach": 0.729, "pressure": 101325.0, "temperature": 288.15,
"direction": { "type": "angles", "angles": { "aoa": 2.31 } },
"turbulence": { "nu_factor": 3.0 } }
]
}
],- The airfoil is a no-slip wall, adiabatic by default.
- The farfield gives the freestream state;
aoais the angle of attack in degrees. nu_factoris the freestream value of the SA variable relative to the laminar viscosity; 3 is the usual choice for a fully turbulent external flow.
Numerical method
"numerical_method": {
"advection": { "limiter": { "type": "venkatakrishnan_wang" } }
},This is the only numerical setting in the deck. The default convective scheme (Roe, second order) has no slope limiter; at the shock the second-order reconstruction then overshoots, and on this mesh the run diverges after about 200 iterations. The Venkatakrishnan–Wang limiter keeps the reconstruction bounded near the shock and leaves it second order in smooth regions. See Further discussion.
Run control
"run_control": {
"cfl": { "type": "adaptive" },
"iteration": 10000,
"convergence": { "type": "monitor", "fields": ["CL", "CD"] }
},cfl.type: adaptive: the CFL number starts at 5 and grows to 100 while the implicit steps are solved well. The default policy, a constant CFL of 10, converges several times slower on steady airfoil cases.iterationis required; here it is only an upper bound.convergence.type: monitorstops the run when every listed monitor has settled: its range over the last 100 iterations is below \(10^{-5}\) (0.1 drag count).CLandCDare the monitors defined inmonitoring.
Outputs
"outputs": {
"volumes": [
{ "name": "flowfield", "file_name": "flow", "format": "vtu",
"frequency": 0, "fields": ["default"] }
],
"surfaces": [
{ "name": "airfoil_surface", "boundary_names": ["airfoil"],
"file_name": "airfoil_surface", "format": "vtu",
"frequency": 0,
"fields": ["Pressure", "PressureCoefficient", "Mach", "Cf", "Yplus"] }
],
"restart": {
"enabled": true, "file_name": "restart_flow", "frequency": 0
}
},frequency: 0 writes a file once, at the end of the run.
volumes: the flow field,flow_<iteration>.pvtu.surfaces: the listed fields on the airfoil,airfoil_surface_AIRFOIL_<iteration>.pvtu.restart:restart_flow_<iteration>.wsol, to continue the run later.
Monitoring
"monitoring": {
"history_files": [
{ "id": "main", "file_name": "history", "frequency": 1,
"enabled": true }
],
"console": { "frequency": 50 },
"monitors": [
{ "name": "CL", "history_file": "main",
"target": { "boundaries": ["airfoil"] },
"function": "force_coefficient",
"direction": [-0.0403061842, 0.9991873756, 0.0],
"console": true },
{ "name": "CD", "history_file": "main",
"target": { "boundaries": ["airfoil"] },
"function": "force_coefficient",
"direction": [0.9991873756, 0.0403061842, 0.0],
"console": true },
{ "name": "CMz", "history_file": "main",
"target": { "boundaries": ["airfoil"] },
"function": "moment_coefficient",
"axis": [0.0, 0.0, 1.0], "console": true }
]
}- The monitors are written every iteration to
history.csvand every 50 iterations to the console. - A force coefficient is the force on the target boundaries along
direction. The lift and drag directions here are for 2.31°: lift along (−sin α, cos α), drag along (cos α, sin α). If you change the angle of attack, change these vectors with it.
Obtaining the solution
Check the deck without running it:
wake_2d_mixed rae2822_sa_defaults.jsonc --validateIt prints
Validation passed.followed by the boundary values it read, and returns exit code 0. A typo in a key name or a missing mesh is reported here with its location in the file.Run the case:
# Linux, one process wake_2d_mixed rae2822_sa_defaults.jsonc # Linux, four MPI processes mpiexec -n 4 wake_2d_mixed rae2822_sa_defaults.jsoncOn Windows use
wake_2d_mixed.exe. For MPI and GPU options see Running Wake CFD.Follow the console. Every 50 iterations the solver prints one line (the spacing between columns is reduced here to fit the page):
Iter Wall/it Flow_Res Turb_NuTilde CFL_Avg CL CD CMz 0 0.0112 0.0000 -4.5004 5.00 0.130052 0.145420 0.052482 50 0.0413 -1.1628 -3.1107 100.00 0.809132 0.017683 0.118442 100 0.0346 -2.6104 -4.4878 100.00 0.748640 0.014015 0.097667Column Meaning Wall/itWall-clock seconds per iteration Flow_ResMean-flow residual in orders of magnitude below its value at the start (0 = start, −3 = a thousand times smaller) Turb_NuTildeResidual of the SA equation CFL_AvgCurrent CFL number — here it reaches the ceiling of 100 within 50 iterations CL,CD,CMzThe monitors of the deck The run stops by itself when CL and CD have settled. The console names the monitor that settled last (
least-settled monitor 'CL'), and the closing summary gives the reason:| Stop reason | Converged (monitor criteria) | | Iterations | 609 |The run takes 609 iterations, a few minutes on a few CPU cores.
The run folder rae2822_sa_defaults_001/ sits next to the deck; a second run of the same deck writes rae2822_sa_defaults_002/.
| File | Contents |
|---|---|
flow_00000609.pvtu (+ one .vtu piece per MPI process) |
Flow field: Mach, Pressure, PressureCoefficient, Density, Temperature, Velocity, EddyViscosity, … |
airfoil_surface_AIRFOIL_00000609.pvtu |
Airfoil surface: Pressure, PressureCoefficient, Mach, Cf, Yplus |
history.csv |
CL, CD, CMz and their pressure and friction parts, every iteration |
solver_residual_reduction.csv |
Residual reduction of each equation, every iteration |
restart_flow_00000609.wsol |
Restart file |
input.jsonc |
The deck as the solver read it, for the record |
Viewing the results in ParaView
Convergence history
In ParaView select File > Open, choose
solver_residual_reduction.csvin the run folder and click Apply. ParaView shows the table in a spreadsheet view.Split the view, choose Line Chart View, and make the table visible in it (eye icon in the Pipeline Browser).
In the Properties panel set:
Property Value Use Index For X Axis (cleared) X Array Name IterationSeries Parameters only Flow_ReductionselectedRepeat with
history.csvand the seriesCL.
The lift settles long before the residual stops falling. The run continues until CL and CD vary by less than the monitor tolerance over the last 100 iterations.
Mach number field
- Select File > Open, choose
flow_00000609.pvtuand click Apply. - In the toolbar choose
Machas the coloring variable. - Click Set view direction to +Z and zoom to the airfoil.
- Optionally set a fixed color range (Rescale to Custom Data Range, 0 to 1.35) so that the sonic value 1 sits in the middle of the color map.
The supersonic pocket over the upper surface and the shock that closes it are the features this case is about. The thin low-speed layer along the surface is the boundary layer, which thickens behind the shock.
Surface pressure coefficient against the experiment
The airfoil surface file holds PressureCoefficient at the 192 surface points. To plot it along the chord, the points must be in order along the surface; ParaView does that with three filters.
Select File > Open, choose
airfoil_surface_AIRFOIL_00000609.pvtuand click Apply.With it selected, apply the following filters in turn (Filters > Alphabetical), clicking Apply after each:
Filter Settings Why Clean to Grid defaults Merges the points that neighboring MPI pieces share Extract Surface defaults Turns the result into lines Plot On Sorted Lines defaults Orders the points along the airfoil and opens a line chart Calculator Result Array Name minus_Cp, expression-PressureCoefficientAirfoil pressure is drawn with suction up; ParaView charts cannot reverse an axis In the line chart’s Properties, clear Use Index For X Axis, set X Array Name to
Points_X(the chord is 1 m, so x is x/c), and select onlyminus_Cpunder Series Parameters.Select File > Open, choose
rae2822_case6_cp_exp.csv(from the tutorial folder) and click Apply.Apply a Calculator to it with Attribute Type
Row Data, Result Array Nameminus_Cp_exp, expression-Cp_exp.Show it in the same line chart: X Array Name
x_c, seriesminus_Cp_exponly, Line Style None, Marker Style Circle.
The computed pressure follows the measurements on both surfaces: the suction peak at the leading edge, the plateau of the supersonic region, the shock at x/c ≈ 0.55 and the recovery behind it. The lift coefficient is 0.743, the same as the measured normal-force coefficient.
The same chart can be produced in one command with the script from the tutorial folder:
pvbatch paraview_cp.py rae2822_sa_defaults_001 cp.pngFurther discussion
Why a limiter. Run the deck once without the numerical_method block. The solver warns repeatedly that MUSCL face states were rejected and fell back to first order, the residual climbs instead of falling, and the run stops after about 200 iterations with Stop reason: Diverged. Smooth subsonic cases, such as a low-speed airfoil, do not need the limiter; cases with shocks do.
Why an adaptive CFL. With the default constant CFL of 10 the same case needs several times as many iterations. The adaptive controller raises the CFL as long as each implicit step is solved well and lowers it when a step goes wrong, so it is a safe first choice for steady cases.
What to compare with the experiment. Compare the pressure distribution and the lift. The drag coefficient of this run (139 counts) is not directly comparable with the measured 127 counts: the measurement was taken at the uncorrected tunnel conditions, and on this comparatively coarse mesh the computed drag still falls as the mesh is refined.
Next steps.
- Change the angle of attack: edit
direction.angles.aoaand the CL and CD direction vectors together, and save the deck under a new name so that each run keeps its own folder. - Input reference for every block: Input-file structure.
- Convergence and scheme choices: Recommended settings and troubleshooting.