2D Laminar Flat-Plate Boundary Layer — Blasius & Pohlhausen Verification

Verification of velocity profiles, wall friction, and wall heat transfer against the exact Blasius and Pohlhausen similarity solutions, across seven convective schemes

Wake CFD flat-plate calculations compared velocity profiles and skin friction with the Blasius solution and heat transfer with the Pohlhausen solution across convective schemes.

1 Run Provenance and Artifacts

Item Value
Solver DBNS
Compute device CPU
Parallel execution 1 MPI rank
Arithmetic precision FP64

1.1 Downloadable Files

Not yet available. Input decks and result files for this case are planned for a future release.

2 Verification Objective

The laminar boundary layer over a two-dimensional flat plate was computed for comparison with analytical solutions. The Blasius solution provided the velocity and skin-friction references, and the Pohlhausen similarity solution provided the heat-transfer reference. The verification assessed:

  • no-slip wall treatment for the velocity boundary layer and isothermal wall treatment for the thermal boundary layer
  • self-similarity of laminar boundary-layer velocity and temperature profiles
  • variation of the local skin-friction coefficient (Cf) and local Nusselt number (Nu_x)
  • low-Mach behavior of DBNS numerical fluxes, across seven convective schemes: five schemes with all-speed/low-Mach treatment (AUSM+up, AUSM+up2, SLAU, SLAU2, Roe-Turkel) and two reference schemes without explicit low-Mach correction (Roe, JST)

Because the laminar flat-plate flow has zero pressure gradient and well-known analytical solutions for both the velocity and thermal boundary layers, it is a useful reference case for checking viscous-wall treatment, low-Mach schemes, numerical diffusion, and wall heat-flux computation together.

3 Reference Solution and Data

3.1 Analytical Solution

Let x be the distance from the leading edge, y the wall-normal distance, U_inf the freestream velocity, and nu the kinematic viscosity. The following nondimensional quantities are used:

\[ Re_x = \frac{U_\infty x}{\nu}, \qquad \eta = y\sqrt{\frac{U_\infty}{\nu x}}. \]

The Blasius solution is expressed as u/U_inf = f'(eta), with the primary comparison values:

\[ \delta_{99}\approx 4.91\sqrt{\frac{\nu x}{U_\infty}}, \qquad C_f(x)=\frac{0.664}{\sqrt{Re_x}}. \]

When velocity profiles at several x/L locations are plotted against eta, they should collapse onto a single curve.

For the thermal boundary layer, with an isothermal wall at temperature T_wall different from the freestream temperature T_inf, the Pohlhausen solution gives the local Nusselt number:

\[ Nu_x = \theta'(0)\sqrt{Re_x}, \qquad \theta'(0) = 0.295635 \text{ for } Pr=0.72, \]

where Pr is the Prandtl number. This case uses T_wall=327.38 K and T_inf=297.62 K with air (Pr≈0.72).

4 Simulation Conditions

Item Setting
Dimension 2D
Domain x=[0, 0.762] m, y=[0, 0.1524] m
Flat plate x=[0.1524, 0.4572] m, L=0.3048 m
Analysis Steady, compressible DBNS, laminar Navier–Stokes
Target Reynolds number Re_L=1.0×10^5
Mach conditions 0.1, 0.05, 0.0144
Wall no-slip, isothermal, T_wall=327.38 K
Freestream temperature T_inf=297.62 K (Pr≈0.72)

Viscosity was adjusted at each Mach number to keep Re_L constant and isolate low-Mach numerical behavior. These are controlled numerical comparisons at a fixed Reynolds number, with different viscosity values. M=0.0144 is a low-speed condition close to physical air viscosity; M=0.1 and M=0.05 compare low-Mach numerical behavior at the same Reynolds number.

5 Mesh

Domain for laminar flat-plate flow simulation

The computational domain consists of buffer regions upstream and downstream of the plate and a boundary-layer resolution region around it. The mesh was refined at the leading edge, trailing edge, and near the wall to resolve boundary-layer velocity gradients and wall shear.

Full 2D flat-plate mesh

Mesh near the flat-plate leading edge

6 Boundary and Initial Conditions

Boundary / mesh marker Location Physical condition Setting
Plate (wall) Plate segment, x=[0.1524, 0.4572] m wall No-slip, isothermal, T_wall=327.38 K
Upstream lower boundary (symmetry) y=0, upstream of the plate symmetry Slip symmetry
Downstream lower boundary (outlet_bottom) y=0, downstream of the plate symmetry Slip symmetry
Inlet (inlet) Left, x=0 farfield M=0.1, 0.05, or 0.0144; p_inf=101325 Pa, T_inf=297.62 K, zero angle of attack
Outlet (outlet) Right, x=0.762 m pressure_outlet Back pressure 101325 Pa
Upper boundary (farfield) Top, y=0.1524 m symmetry Slip symmetry

Mesh marker names identify boundary segments; the physical condition is assigned separately. In particular, outlet_bottom and the upper farfield marker both use symmetry conditions, while the left inlet marker uses a farfield condition.

Each calculation started from a uniform freestream field with p=101325 Pa, T=297.62 K, the Mach number of that calculation (0.1, 0.05, or 0.0144), and flow direction [1,0,0]. The isothermal no-slip plate develops the velocity and thermal boundary layers from this initial field.

7 Numerical Methods

Item Setting
Analysis Steady, compressible DBNS, laminar Navier–Stokes
Convective schemes AUSM+up, AUSM+up2, SLAU, SLAU2, Roe-Turkel, Roe, JST (compared below)
Spatial accuracy Second order, Venkatakrishnan limiter
Time integration Euler implicit (steady solution)
CFL Adaptive, 1 → 100
Convergence criterion Cauchy-window monitor on the total streamwise force coefficient CFx (eps=1e-5 over a 1000-iteration window)

The CLI and Domain and Boundary Conditions sections of the Wake CFD User Guide describe the input structure and boundary-condition definitions used in this calculation.

7.1 Numerical Schemes Compared

The 21 cases covered seven DBNS convective schemes at each of the three Mach numbers: five schemes designed for accuracy across a wide Mach range (AUSM+up, AUSM+up2, SLAU, SLAU2, Roe-Turkel, the last using a Turkel low-Mach preconditioner), and two reference schemes with no explicit low-Mach treatment (Roe, JST), included to evaluate their accuracy as Mach number decreases.

8 Results

8.1 Scheme comparison

Method Low-Mach treatment Result summary (M=0.1 → 0.0144)
AUSM+up, AUSM+up2, SLAU, SLAU2 All-speed flux formulation Close to Blasius/Pohlhausen at every Mach; no degradation
Roe-Turkel Turkel preconditioner Close to Blasius/Pohlhausen at every Mach; converges in roughly 1/3–1/4 the iterations of the other schemes
Roe None Close to Blasius/Pohlhausen at every Mach — comparable to the all-speed group in this case
JST None Visibly degrades as Mach decreases; used here as the low-Mach control case

The scheme comparison used the same flat-plate mesh and a fixed Reynolds number. In this configuration, Roe retained accuracy down to M=0.0144 without explicit low-Mach preconditioning. The scheme comparison and its applicable scope are summarized in Conclusions and Applicable Scope.

Two whole-plate accuracy metrics were used to assess all seven schemes at each Mach number: the mean ratio of computed skin friction to the Blasius reference, Cf/Cf_Blasius, and the mean ratio of computed local Nusselt number to the Pohlhausen reference, Nu_x/Nu_x,Pohlhausen, both averaged over x/L=0.03–0.95 (both are unweighted point-wise means, not force-integrated coefficients; ratios near 1.00 indicate agreement).

Scheme M Velocity RMS (x/L=.25,.50,.75) Cf/Cf_Blasius Nu_x/Nu_x,Pohlhausen
AUSM+up2 0.1 / 0.05 / 0.0144 0.7–1.1% at all three 1.02–1.03 0.98 → 1.00
AUSM+up 0.1 / 0.05 / 0.0144 0.7–1.1% at all three 1.02–1.03 0.98 → 1.00
SLAU2 0.1 / 0.05 / 0.0144 0.7–1.1% at all three 1.02–1.03 0.98 → 1.00
SLAU 0.1 / 0.05 / 0.0144 0.7–1.1% at all three 1.02–1.03 0.98 → 1.00
Roe-Turkel 0.1 / 0.05 / 0.0144 0.7–1.0% at all three 1.02 0.98 → 1.00
Roe 0.1 / 0.05 / 0.0144 0.7–1.1% at all three 1.02 0.98 → 1.01
JST 0.1 / 0.05 / 0.0144 1.0–1.2% → 2.2–3.3% 1.09 → 1.16 0.99 → 1.02

The five all-speed schemes and Roe gave mean Nu_x/Nu_x,Pohlhausen ratios near unity throughout the Mach range. For the five all-speed schemes, the heat-transfer difference decreased from roughly −2% at M=0.1 to within +0.5% at M=0.0144. The detailed Roe results below show the corresponding change from 0.981 to 1.005. Six schemes maintained nearly constant velocity and skin-friction accuracy as Mach decreased. JST showed a different trend: its velocity and skin-friction errors increased, and its mean Nusselt-number ratio rose from about 0.99 to 1.02.

All seven schemes, M=0.1: velocity profile (x/L=0.5), skin friction, and Nusselt number

All seven schemes, M=0.05: velocity profile (x/L=0.5), skin friction, and Nusselt number

All seven schemes, M=0.0144: velocity profile (x/L=0.5), skin friction, and Nusselt number

At M=0.1 all seven curves are essentially indistinguishable. As Mach decreases, JST (shown in red) separates visibly from the rest, while the five all-speed schemes and Roe remain clustered on the reference curves even at M=0.0144.

8.2 Closer Look: Roe Without Low-Mach Preconditioning

A detailed comparison of Roe and Roe-Turkel assessed the effect of adding a Turkel low-Mach preconditioner to the same base scheme. The table and figures below give the velocity profiles at all three stations (x/L=0.25, 0.50, 0.75), skin friction, and heat transfer for each Mach number. These results also form the basis of the summary above.

M Velocity RMS (x/L=.25,.50,.75) δ99(η) (x/L=.25,.50,.75) Cf/Cf_Blasius Nu_x/Nu_x,Pohlhausen
0.1 0.68%, 0.67%, 0.96% 4.71, 4.61, 4.49 1.021 0.981
0.05 0.70%, 0.70%, 0.99% 4.70, 4.60, 4.49 1.021 0.995
0.0144 0.78%, 0.72%, 1.06% 4.71, 4.59, 4.47 1.022 1.005

(The Blasius reference value of δ99(η) is approximately 4.9.)

Roe, M=0.1: velocity profiles at three stations, skin friction, and Nusselt number

Roe, M=0.05: velocity profiles at three stations, skin friction, and Nusselt number

Roe, M=0.0144: velocity profiles at three stations, skin friction, and Nusselt number

For qualitative reference, the two contour plots below (M=0.1) show the velocity and temperature fields near the leading edge, illustrating the developing momentum and thermal boundary layers on the isothermal wall.

Roe, M=0.1: velocity-magnitude contour near the leading edge

Roe, M=0.1: temperature contour near the leading edge

9 Conclusions and Applicable Scope

  • The five all-speed schemes (AUSM+up, AUSM+up2, SLAU, SLAU2, Roe-Turkel) agree well with both the Blasius velocity profile and the Pohlhausen heat-transfer solution from M=0.1 down to M=0.0144, and are essentially indistinguishable from one another on this case.
  • Roe-Turkel reaches its converged state in roughly 1/3–1/4 the iterations of the other six schemes at the same Mach numbers; its practical advantage here is convergence speed rather than accuracy.
  • JST, evaluated without low-Mach correction, showed increasing velocity and skin-friction errors as Mach decreased. This quantified its low-Mach sensitivity for the present flat-plate configuration.
  • Without explicit low-Mach correction, Roe remained close to the all-speed group down to M=0.0144 on the specified mesh at the fixed Reynolds number. This finding applies to the flat-plate configuration evaluated here.
  • The verification covered a 2D, steady, zero-pressure-gradient laminar flat-plate boundary layer at Re_L=1×10^5, using one mesh and the specified wall-temperature ratio. Grid-resolution, Reynolds-number, and wall-temperature-ratio sensitivity, as well as turbulence, curved surfaces, separation, and transition, were outside this verification scope.

This verification documents the accuracy and convergence behavior of seven DBNS convective schemes for the specified low-Mach, isothermal flat-plate conditions. It provides a common reference for comparing velocity profiles, wall friction, and wall heat transfer across these schemes.

10 References

  • Blasius, H., “Grenzschichten in Flüssigkeiten mit kleiner Reibung,” Zeitschrift für Mathematik und Physik, 56, 1908, pp. 1–37.
  • Pohlhausen, E., “Der Wärmeaustausch zwischen festen Körpern und Flüssigkeiten mit kleiner Reibung und kleiner Wärmeleitung,” Zeitschrift für Angewandte Mathematik und Mechanik, 1, 1921, pp. 115–121.
  • White, F.M., Viscous Fluid Flow, 3rd ed., McGraw-Hill, 2006 (Blasius and Pohlhausen similarity solutions, Chapter 4).