2D Transonic Airfoil — RAE2822 RANS Validation

Comparison of shock location and surface pressure distribution against the AGARD Case 6 experiment

Wake CFD calculations of the RAE2822 transonic airfoil were compared with AGARD Case 6 measurements of surface pressure, shock location, and normal force.

1 Run Provenance and Artifacts

Item Value
Solver DBNS
Compute device CPU
Parallel execution 1 MPI rank
Arithmetic precision FP64

1.1 Downloadable Files

Not yet available. Standalone input decks and solver result files for this case are planned for a future release.

2 Validation Objective

For a transonic airfoil, small changes in conditions can substantially alter the shock location and lift. The validation compared the computed RAE2822 shock location and force coefficient with AGARD Case 6 measurements, using the surface pressure distribution to assess the shock.

The assessment considered the pressure distribution and force level together. The termination behavior was also compared across eight convective schemes.

3 Reference Solution and Data

Item Setting
Reference AGARD AR-138 RAE2822 Case 6 pressure distribution and normal-force coefficient (C_N=0.743)

4 Simulation Conditions

Item Setting
Geometry RAE2822 2D airfoil
Analysis Steady, compressible RANS
Freestream Mach 0.729
Angle of attack 2.31°
Reynolds number Re_c=6.5×10^6
Reference temperature 288.15 K
Freestream pressure 101325 Pa
Material Ideal-gas air, gamma=1.4, R=287.87 J/(kg·K); constant mu=4.6686×10^-5 Pa·s, Pr=0.72
Reference geometry Chord 1 m, area 1 m², moment center [0.25,0,0] m

The Case 6 comparison used the free-air condition M=0.729 and alpha=2.31°. The published wind-tunnel condition is M=0.725, alpha=2.92°. The pressure and force references used below are from Case 6.

5 Mesh

Item Setting
Mesh 2D C-mesh, 192 points on the airfoil surface

The baseline mesh is a 2D C-mesh with 192 points on the airfoil surface, comprising 13,937 nodes and 22,842 elements. The airfoil surface and near field where the shock forms are refined, with progressively coarser spacing toward the farfield.

Full domain of the RAE2822 Case 6 baseline C-mesh

Leading-edge region of the RAE2822 Case 6 baseline C-mesh

6 Boundary and Initial Conditions

Boundary / mesh marker Condition Setting
Airfoil (AIRFOIL) No-slip, adiabatic wall RAE2822 surface
Outer boundary (FARFIELD) Farfield M=0.729, p=101325 Pa, T=288.15 K, direction [0.99919,0.04031,0], nu_tilde/nu=3

The auto initialization used the uniform farfield state, including the SA freestream condition nu_tilde/nu=3. Flow was in the x–y plane; the specified direction corresponds to an angle of attack of 2.31°.

7 Numerical Methods

Item Setting
Turbulence model Spalart–Allmaras (SA)
Convective schemes Roe, HLLC, JST, AUSM+up, AUSM+up2, SLAU, SLAU2, and AUSM (compared below)

The calculations used implicit time integration, weighted-least-squares gradients, and a Venkatakrishnan-family limiter with coefficient 0.01. The linear solver was FGMRES with DILU preconditioning, relative tolerance 0.01, and a maximum of 25 linear iterations. CFL was fixed at 5, except for AUSM at 2.5. Residual settings specified an eight-order reduction and an absolute log10 target of -8, with a maximum of 20,000 iterations.

8 Results

8.1 Key Results

The reported force values are chord-normal coefficients (C_N, solver CFy). At this small angle they approximate lift. The comparison used the Case 6 normal-force reference of 0.743.

The Roe calculation met the residual-reduction criterion in 4,697 iterations and predicted C_N=0.7455, a 0.3% difference from the Case 6 normal-force reference of 0.743. The suction-side shock was also captured near the experimental location, x/c≈0.55.

The Mach contour shows the flow accelerating over the suction side to form a local supersonic region, followed by sharp compression near x/c≈0.55. The pressure-coefficient contour likewise shows a distinct pressure recovery at the same location, consistent with the shock location identified in the surface pressure comparison.

RAE2822 Case 6 — Roe-scheme Mach contour

RAE2822 Case 6 — Roe-scheme pressure-coefficient contour

RAE2822 Case 6 — comparison of Wake CFD Roe results with AGARD experiment and NASA WIND 5.0 SA results

RAE2822 Case 6 — surface pressure-coefficient distribution from the Roe scheme, compared with experiment and NASA WIND

The pressure-distribution shape on both sides of the shock and the pressure recovery were compared with the experimental points. The assessment combined shock location, surface pressure, and normal-force coefficient.

8.2 Comparisons for Scheme Selection

All eight schemes were compared on the same mesh with the same turbulence model. The table gives the normal-force coefficient, iteration count, and termination behavior for each scheme. The AUSM result used CFL 2.5; the other results used CFL 5.

Scheme Normal-force coefficient C_N Iterations Convergence status
Roe 0.7455 4,697 Converged
HLLC 0.7471 4,693 Converged
JST 0.7266 5,205 Converged
AUSM+up 0.7564 4,663 Converged
AUSM+up2 0.7383 4,712 Converged
SLAU / SLAU2 0.7404 / 0.7385 20,000 Residual stagnation*
AUSM 0.7589 20,000 Leading-edge oscillation

* The pressure distribution and force coefficients stabilized, but the specified residual-reduction criterion was not reached.

RAE2822 Case 6 — surface pressure-coefficient distribution with HLLC

RAE2822 Case 6 — surface pressure-coefficient distribution with JST

RAE2822 Case 6 — surface pressure-coefficient distribution with AUSM+up

RAE2822 Case 6 — surface pressure-coefficient distribution with AUSM+up2

RAE2822 Case 6 — surface pressure-coefficient distribution with SLAU

RAE2822 Case 6 — surface pressure-coefficient distribution with SLAU2

RAE2822 Case 6 — surface pressure-coefficient distribution with AUSM

9 Conclusions and Applicable Scope

  • Roe gave C_N=0.7455, about 0.3% above the Case 6 normal-force reference 0.743, and captured the suction-side shock near x/c≈0.55.
  • Roe, HLLC, JST, AUSM+up, and AUSM+up2 met the configured residual-reduction criterion. Their pressure distributions reproduced the measured shock and pressure recovery.
  • SLAU and SLAU2 reached 20,000 iterations with stable pressure and force distributions but without meeting the residual-reduction criterion. AUSM reached the iteration limit with leading-edge pressure oscillations.
  • The evaluation covered the RAE2822 baseline mesh at M=0.729, alpha=2.31°, and Re_c=6.5×10^6 with steady, two-dimensional SA RANS. The comparison documents surface pressure, shock location, normal force, and termination behavior under these settings.

10 References