Laminar Flow in a 90° Tee Junction

Re = 300, flow split and grid convergence at equal outlet static pressures

Steady 2D laminar flow through a 90° tee junction at Re = 300 was computed with the pressure-based solver in Wake CFD. The main-branch flow fraction was compared with Hayes et al.’s finite-element results at equal outlet static pressures, and convergence was assessed on four meshes.

Tee junction with the inlet at the bottom, the main-branch outlet at the top, and the side-branch outlet on the right.

1 Run Provenance and Artifacts

Item Value
Solver PBNS, steady incompressible laminar flow
Compute device CPU
Parallel execution 1 MPI rank for every run
Arithmetic precision Mixed

1.1 Downloadable Files

File Description Format Size
Grid convergence results Cell sizes, iteration counts, flow splits, mass-balance errors, and relative differences from the reference for four meshes, with the Richardson extrapolation, observed order, and grid convergence index CSV 312 B

The input decks, meshes, raw solver results, and analysis scripts are currently unavailable and are planned for a future release.

2 Verification Objective

Steady laminar flow through a planar 90° tee junction was computed using the pressure-based Navier–Stokes solver (PBNS). Flow entered through the lower inlet and divided between the straight-through main branch (upper outlet) and the perpendicular side branch (right outlet). Both outlets had the same prescribed static pressure. The flow split is the fraction of the inlet flow leaving through the main-branch outlet:

\[ \text{split} = \frac{Q_\text{upper}}{Q_\text{inlet}} \]

The flow split was compared with the finite-element results of Hayes et al. (1989). The assessment on four meshes included the observed order, Richardson extrapolation, and grid convergence index (GCI). The combined outlet flow was compared with the inlet flow to check mass balance. The domain-length study extended both outlet legs from \(3W\) to \(6W\), where \(W\) is the inlet width.

3 Reference Solution and Data

3.1 Numerical Reference

Hayes et al. (1989) computed steady laminar flow through a planar 90° tee junction using a Galerkin finite-element method. They used the Crouzeix–Raviart triangular element, with quadratic velocity interpolation enriched by a bubble function at the element centroid and linear pressure interpolation.

Figure 6 of the paper plots the fraction of flow leaving through the main branch as a function of Reynolds number for several side-branch widths. Both outlets had the same static pressure, and both outlet legs were \(L=3W\) long. The numerical reference of 0.887 was read from the curve for a side-branch width of \(W\) at \(Re=300\).

The gray band in the grid convergence figure shows the rounding interval (±0.0005) associated with reporting the reference to three decimal places. For \(L=3W\) and \(Re\le600\), Hayes et al. reported changes in the flow split of less than 2% when refining the element subdivisions per unit square from 5 × 5 to 10 × 10.

4 Simulation Conditions

Item Setting
Geometry Main channel width \(W=1\) m (\(0\le x\le1\) m). The inlet leg was 2 m long. The side branch was \(W\) wide and extended \(L=3\) m from the right wall of the main channel. The main-branch outlet leg extended \(L=3\) m from the upper wall of the side branch.
Flow Steady, incompressible laminar flow. The energy equation was disabled.
Density \(\rho=1\) kg/m³
Dynamic viscosity \(\mu=0.003333\) Pa·s
Reference velocity Inlet centerline velocity \(V_c=1\) m/s
Reynolds number \(Re=\rho V_c W/\mu\approx300\), based on the inlet centerline velocity as in the reference
Outlet-leg length sensitivity Both outlet legs extended to \(L=6\) m, with 40 cells per \(W\)

5 Mesh

The Gmsh hexahedral mesh comprised four blocks covering the inlet leg, the tee junction, the main-branch outlet leg, and the side branch. A Bump coefficient of 0.2 clustered cells near both walls across each channel. Cell spacing was uniform along the channels. A single extruded cell of thickness \(W/n\) in the \(z\) direction represented the planar flow, where \(n\) is the number of cells across the channel width \(W\).

Mesh (cells per \(W\)) Cell size \(h/W\) Cells Nodes
10 0.1 900 2,002
20 0.05 3,600 7,602
40 0.025 14,400 29,602
80 0.0125 57,600 116,802
40 (\(L=6\)) 0.025 24,000 49,282

For \(L=3W\), the cell size halved with each of the three refinement steps. All four meshes used the same physical and numerical settings.

Full domain with 20 cells per channel width and a close-up of the junction with 40 cells per channel width.

6 Boundary and Initial Conditions

Boundary or field Setting
Inlet (\(y=0\)) Velocity inlet with a fully developed parabolic profile \(v=4x(1-x)\) m/s, centerline velocity \(V_c=1\) m/s, and mean velocity \(2/3\) m/s
Main-branch outlet Pressure outlet at a static pressure of 101,325 Pa
Side-branch outlet Pressure outlet at the same static pressure of 101,325 Pa
Walls No slip on all walls
Front and back faces Symmetry on both faces of the one-cell extrusion
Initial field Uniform upward velocity (\(+y\)) of \(v=0.6667\) m/s, corresponding to the inlet mean velocity of \(2/3\) m/s, and uniform pressure of 101,325 Pa

7 Numerical Methods

The flow linear system was solved with FGMRES and an algebraic multigrid (AMG) preconditioner, using a tolerance of \(10^{-3}\) and a limit of 50 iterations per linear solve. Pseudo-time marching used a local convective CFL of 20. The outer iteration limit was 3,000. The stopping criterion was either a scaled flow residual of \(10^{-10}\) or less, or a base-10 logarithm of the absolute residual metric of \(-15\) or less. All five runs met the stopping criterion in 143–588 iterations.

Flow rates per unit depth (m²/s) were obtained by trapezoidal integration of the normal velocity along the inlet (\(y=0\)) and the two outlet node lines in the plane at the minimum \(z\) coordinate. The flow splits on the three finest meshes (20, 40, and 80 cells per \(W\)) were used to calculate the observed order, Richardson extrapolation, and GCI.

8 Results

8.1 Grid Convergence

Mesh (cells per \(W\)) Iterations \(Q_\text{inlet}\) \(Q_\text{upper}\) \(Q_\text{side}\) Mass-balance error Flow split Difference from reference
10 143 0.65646 0.58328 0.07315 \(-5.10\times10^{-5}\) 0.8885 +0.17%
20 204 0.66409 0.58875 0.07533 \(-2.51\times10^{-5}\) 0.8865 −0.05%
40 338 0.66602 0.59009 0.07593 \(-8.12\times10^{-6}\) 0.8860 −0.11%
80 588 0.66651 0.59039 0.07611 \(-2.75\times10^{-6}\) 0.8858 −0.14%
Richardson extrapolation 0.8857 −0.15%

The mass-balance error is \((Q_\text{upper}+Q_\text{side})/Q_\text{inlet}-1\). The flow rates are per unit depth in m²/s.

The flow split decreased monotonically from 0.8885 to 0.8865, 0.8860, and 0.8858 as the mesh was refined. The three finest meshes gave an observed order of 1.56, a Richardson-extrapolated value of 0.8857, and a finest-mesh GCI of ±0.014%. The difference from the extrapolated value on the coarsest mesh (10 cells per \(W\)) fell below the trend line for order 1.56, placing that mesh outside the asymptotic convergence range.

The finest-mesh flow split was 0.0012 (0.14%) below the reference of 0.887, and the extrapolated value was 0.15% below it. Both absolute differences exceeded the reference rounding half-width of 0.0005. These relative differences were about ten times the finest-mesh GCI and below the 2% bound on grid sensitivity reported in the reference.

The exact inlet flow per unit depth is \(2/3\) m²/s, obtained by integrating the prescribed parabolic profile across the inlet width. The computed inlet flow was 1.5% below this value on the mesh with 10 cells per \(W\) and 0.02% below it on the mesh with 80 cells per \(W\). With the same quadrature applied to the inlet and outlet flow rates, much of this error canceled in the flow split. The magnitude of the mass-balance error decreased from \(5.10\times10^{-5}\) to \(2.75\times10^{-6}\).

Flow split, difference from the extrapolated value, and mass-balance error plotted against cell size.

8.2 Flow Field

A recirculation zone formed along the lower wall of the side branch (\(y=2\) m). On the finest mesh, reverse flow at the nodes nearest that wall extended from \(x\approx1.0\) m to \(x\approx2.55\) m, a length of about \(1.5W\). No reverse flow was observed along the main-branch walls or the upper wall of the side branch. The pattern was consistent with the cavity-like side-branch flow that Hayes et al. observed as the Reynolds number increased.

Velocity magnitude and streamlines on the mesh with 80 cells per channel width.

8.3 Sensitivity to Outlet-Leg Length

The length study extended both the main- and side-branch outlet legs from \(3W\) to \(6W\). With 40 cells per \(W\) and the same physical and numerical settings, the longer-domain calculation reached the stopping criterion in 487 iterations.

Length of each outlet leg Nodes Iterations \(Q_\text{upper}\) \(Q_\text{side}\) Flow split
\(3W\) 29,602 338 0.59009 0.07593 0.8860
\(6W\) 49,282 487 0.54213 0.12389 0.8140

Extending both outlet legs reduced the fraction leaving through the main branch from 0.8860 to 0.8140, a decrease of about 8%. The side-branch flow rate increased to about 1.6 times its original value, and the recirculation zone in that branch shortened. Thus, the flow split depended on the outlet-leg length under equal outlet static pressures. The comparison with 0.887 used the \(L=3W\) domain, matching the domain length used for Figure 6 of the reference.

Velocity magnitude and streamlines for the two outlet-leg lengths.

9 Conclusions and Applicable Scope

Steady 2D laminar flow through a tee junction at \(Re=300\) was computed on four meshes. The side branch had a width of \(W\), both outlet legs were \(3W\) long, and both outlets had the same static pressure. All four runs met the residual stopping criterion. The finest-mesh flow split of 0.8858 and the Richardson-extrapolated value of 0.8857 were 0.14% and 0.15% below the numerical reference of 0.887 from Hayes et al. (1989), respectively. The flow split converged monotonically, with an observed order of 1.56 on the three finest meshes and a finest-mesh GCI of ±0.014%. The magnitude of the mass-balance error on the finest mesh was \(2.75\times10^{-6}\).

Extending both outlet legs from \(3W\) to \(6W\) reduced the flow split from 0.8860 to 0.8140. The quantitative comparison with the reference covered the \(2W\) inlet leg and \(3W\) outlet legs at the fluid properties, Reynolds number, and boundary conditions documented here. The length sensitivity study covered the \(6W\) outlet legs at those same conditions.

10 References

  • Hayes, R. E., Nandakumar, K., and Nasr-El-Din, H. “Steady laminar flow in a 90 degree planar branch.” Computers & Fluids, 17(4), 1989, pp. 537–553.