2D Coflowing Jet — NASA TMR SA Verification

Code-to-code verification of thin-plate drag and free-shear-layer development against CFL3D and FUN3D, five-level grid convergence

A planar coflowing jet was computed with Wake CFD’s Spalart–Allmaras model. Plate drag, shear-layer development, and grid convergence across five mesh levels were assessed against NASA TMR reference calculations.

1 Run Provenance and Artifacts

Item Value
Solver DBNS
Compute device GPU (NVIDIA RTX 5060 Ti, 8 GB)
Arithmetic precision FP64

1.1 Downloadable Files

Not yet available. Standalone input decks and solver result files for this case are planned for a future release.

2 Verification Objective

SA calculations modeled a compressible jet (M≈0.5) and coflow (M≈0.25) separated by a zero-thickness plate. Plate drag, downstream centerline velocity, and velocity and eddy-viscosity profiles were compared with the CFL3D and FUN3D numerical references on the five-level grid family of the NASA TMR 2D Coflowing Jet case.

3 Reference Solution and Data

The TMR coflowing-jet case places a zero-thickness splitter plate (adiabatic, no-slip on both sides) between an inner jet stream and an outer coflow stream. Downstream of the plate trailing edge, the two streams merge into a free-shear layer. The reference solutions (CFL3D, cell-centered; FUN3D, node-centered) are computed on the same mesh family, both using the Roe scheme, which makes the comparison a genuine code-to-code discretization check rather than a physical-model comparison. Reference values are taken directly from TMR’s published convergence.dat and profile data files.

Item Setting
References CFL3D and FUN3D, both SA + Roe FDS on the same mesh, published by NASA TMR

4 Simulation Conditions

Item Setting
Geometry Splitter plate at −10 < x < 0, y = 0.5 (zero thickness); domain −10 < x < 200, 0 < y < 100
Analysis Steady, compressible DBNS, RANS (Spalart–Allmaras)
Inner jet stream Pt/p∞ = 1.1862, Tt/T∞ = 1.050 (M ≈ 0.5)
Outer coflow stream Pt/p∞ = 1.046, Tt/T∞ = 1.000 (M ≈ 0.25)

One grid-length unit corresponded to 1 m. The ideal-gas constants were γ=1.4 and R=287.87 J/(kg·K). The fluid model used Pr=0.72 and Sutherland viscosity with μ(300 K)=4.0796×10^-3 Pa·s and S=110.4 K to match Re=50,000 per unit length.

5 Mesh

Item Setting
Mesh Unstructured quadrilateral, single-cell spanwise extrusion; five-level nested grid family, 1,280–327,680 cells

6 Boundary and Initial Conditions

Layout and boundary conditions of the coflowing-jet case (schematic), with a close-up of the splitter plate

The schematic was drawn from the simulation inputs and the geometry published by NASA TMR (inflow at x = -10, outflow at x = 200, splitter plate at y = 0.5).

Boundary Condition
Inner jet inflow (y < 0.5) Total-pressure inlet, p_t = 120,191.7 Pa (p_t/p∞ = 1.1862), T_t = 315 K (T_t/T∞ = 1.050), flow direction +x
Outer coflow inflow (y > 0.5) Total-pressure inlet, p_t = 105,986 Pa (p_t/p∞ = 1.046), T_t = 300 K (T_t/T∞ = 1.000), flow direction +x
Outflow (x = 200) Pressure outlet, back pressure 101,325 Pa (p/p∞ = 1.0)
Jet centerline (y = 0) Symmetry
Upper boundary (y = 100) Symmetry (not a farfield condition)
Splitter plate, both sides No-slip, adiabatic wall
Spanwise faces Symmetry (the mesh is a one-cell extrusion)

The reference state is p∞ = 101,325 Pa and T∞ = 300 K (540 °R in the TMR specification), M_ref = 0.5, and Re = 50,000 per unit grid length. The turbulence working variable at both inflows is ν̃/ν∞ = 3. The initial field is uniform, with M = 0.5, p = 101,325 Pa, T = 300 K, and flow direction +x.

7 Numerical Methods

Item Setting
Convective scheme Roe, UMUSCL (κ=0.5), no limiter
Gradient method Green–Gauss
Pseudo-time integration Euler implicit
CFL Constant, 50
SA model settings Standard, ft2=true, shat_form=floor, turbulence CFL multiplier 0.4
Viscous gradients / linear solver Corrected average viscous gradient; FGMRES/DILU, maximum 50 linear iterations, tolerance 0.01
Convergence criterion Absolute residual ≤ -12 (log10 RMS of the flow-equation residual)

8 Results

8.1 Grid Convergence

Reference profile and contour data are published only for the finest grid level; grid-convergence trajectories are compared across all five levels using TMR’s published convergence table.

Plate-drag-coefficient grid convergence, Wake CFD versus CFL3D and FUN3D, five grid levels

Centerline-velocity grid convergence at three downstream stations, Wake CFD versus CFL3D and FUN3D
Grid level Cells Cd (Wake CFD) Cd (CFL3D) Cd (FUN3D) Wake CFD vs. FUN3D
4 (coarsest) 1,280 5.0172e-3 6.7104e-3 5.6094e-3 −10.6%
3 5,120 5.5485e-3 6.0111e-3 5.5304e-3 +0.33%
2 20,480 5.5865e-3 5.8473e-3 5.5453e-3 +0.74%
1 81,920 5.6228e-3 5.7914e-3 5.6075e-3 +0.27%
0 (finest) 327,680 5.6603e-3 5.7658e-3 5.6648e-3 −0.08%

The finest-grid drag coefficient differed from FUN3D by −0.08% and from CFL3D by approximately −1.8%. On the coarsest grid, the difference from FUN3D was −10.6%. Wake CFD’s Cd increased monotonically from 5.0172×10^-3 to 5.6603×10^-3 with refinement. FUN3D decreased between the two coarsest levels before increasing, showing a different convergence trajectory.

From coarsest to finest, the five runs reached an absolute flow residual of −12 at iterations 2,211, 5,012, 16,499, 59,381, and 218,173. Plate drag was normalized using reference density 1.173273 kg/m³, velocity 173.857 m/s, and area 10 m².

Centerline velocity u/a∞ at the three downstream stations on the finest grid, with a∞=347.714 m/s:

Station Wake CFD CFL3D FUN3D
x = 2.71623 0.50055 0.50060 0.50049
x = 29.2468 0.41692 0.41717 0.41625
x = 95.501 0.32737 0.32748 0.32712

On the finest grid, all three station velocities differed from either reference code by less than 0.2%.

8.2 Detailed Comparison on the Finest Grid

Downstream centerline- and station-velocity profiles on the finest grid, Wake CFD versus CFL3D and FUN3D

Eddy-viscosity profile at x=29.2468 on the finest grid, Wake CFD versus CFL3D and FUN3D

Eddy-viscosity contours in the far field on the finest grid, Wake CFD versus CFL3D and FUN3D

On the finest grid, Wake CFD’s velocity profiles, eddy-viscosity profile, and eddy-viscosity contours are visually indistinguishable from both reference codes.

9 Conclusions and Applicable Scope

  • On the finest grid, plate drag differed from FUN3D by −0.08% and from CFL3D by approximately −1.8%; the three station velocities differed from either reference code by less than 0.2%.
  • The grid comparison covered drag and centerline-velocity changes across five levels. Wake CFD’s drag increased monotonically with refinement and was 10.6% below FUN3D on the coarsest level.
  • The evaluation covered a planar free-shear layer with Re=50,000 per unit length, jet M≈0.5, coflow M≈0.25, and a zero-thickness adiabatic no-slip plate. The SA results were compared with published numerical references on the same grid family.

10 References

  • NASA Turbulence Modeling Resource, 2D Coflowing Jet Verification Case and SA Expected Results.
  • Bradbury, L. J. S., and Riley, J., “The Spread of a Turbulent Plane Jet Issuing into a Parallel Moving Airstream,” Journal of Fluid Mechanics, 27(2), 1967, pp. 381–394.