Natural Convection in a Horizontal Annulus
Boussinesq and ideal-gas density models against Kuehn and Goldstein’s measurements
1 Run Provenance and Artifacts
| Item | Value |
|---|---|
| Solver | PBNS, steady laminar flow with buoyancy and thermal energy |
| Compute device and precision | CPU, mixed precision |
| Parallel execution | 1 MPI rank for the reported results |
1.1 Downloadable Files
| File | Description | Format |
|---|---|---|
| Boussinesq grid results | Mesh sizes, equivalent conductivity, temperatures, and convergence | CSV |
| Ideal-gas grid results | The same metrics with temperature-dependent density | CSV |
The input decks, meshes, raw solver fields, and post-processing scripts are not yet available and are planned for a future release.
2 Validation Objective
Steady natural-convection heat transfer between horizontal concentric cylinders at \(Ra_L\approx4.9\times10^4\) was computed using Wake CFD’s pressure-based Navier–Stokes solver (PBNS). Equivalent thermal conductivity was compared with the measurements of Kuehn and Goldstein (1978) on four mesh levels to assess the grid trend and the differences from the experimental reference. The Boussinesq and temperature-dependent ideal-gas density models used the same geometry and mesh family.
3 Reference Solution and Data
3.1 Experimental Data
Kuehn and Goldstein reported overall heat transfer in concentric horizontal annuli over a range of Rayleigh numbers. Their equivalent conductivity is the heat transfer divided by that for pure conduction:
\[ k_{\mathrm{eq}}=\frac{Q}{Q_{\mathrm{conduction}}},\qquad Q_{\mathrm{conduction}}= \frac{2\pi k L_z(T_i-T_o)}{\ln(R_o/R_i)}. \]
For the stated diameter ratio, the reference was based on the two experimental values in Table 1 that bracketed the simulated condition: \(k_{\mathrm{eq}}=2.89\) at \(Ra_L=3.20\times10^4\) and 3.32 at \(6.19\times10^4\). Log–log interpolation to \(Ra_L=4.9\times10^4\) gives 3.161. This interpolated value, rather than a measurement at precisely the simulation Rayleigh number, is the reference used below.
The cited overall heat-transfer measurements used pressurized nitrogen (\(Pr\approx0.717\)). The simulation uses constant-property air (\(Pr\approx0.707\)) at a similar Rayleigh number and the same diameter ratio. The difference in fluid and the interpolation are part of the comparison’s uncertainty; the reference is not an exact solution.
4 Simulation Conditions
| Item | Setting |
|---|---|
| Geometry | Horizontal concentric cylinders, \(R_i=17.8\) mm and \(R_o=46.25\) mm |
| Fluid and regime | Air, steady laminar natural convection |
| Inner and outer temperatures | \(T_i=373\) K and \(T_o=327\) K |
| Gravity | \((0,-9.81,0)\) m/s² |
| Gap-based parameters | \(L=28.45\) mm, \(Ra_L\approx4.9\times10^4\), \(Pr\approx0.707\) |
| Constant properties | \(\mu=2.081\times10^{-5}\) Pa·s, \(c_p=1008\) J/(kg·K), \(k=0.02967\) W/(m·K) |
| Density treatments | Boussinesq: \(\rho_0=1.008535\) kg/m³, \(\beta=1/350\) K⁻¹; ideal gas: \(\rho=p/(RT)\) with full density variation |
5 Mesh
A half-annulus (\(x\geq0\)) is discretized with 20 × 60, 40 × 120, 80 × 240, and 160 × 480 radial × azimuthal cells. Each in-plane resolution doubles between levels. The two-dimensional plane is extruded one cell in the spanwise direction for the three-dimensional PBNS solver. The resulting meshes have 2,562, 9,922, 39,042, and 154,882 nodes, respectively. The finest results shown here were computed with one MPI rank.
6 Boundary and Initial Conditions
| Boundary or field | Setting |
|---|---|
| Inner cylinder | Stationary no-slip wall at 373 K |
| Outer cylinder | Stationary no-slip wall at 327 K |
| Cut plane through cylinder centers | Symmetry on the upper and lower half-annulus edges |
| Front and back planes | Symmetry across the one-cell extrusion |
| Initial field | Zero flow at 350 K and 101,325 Pa |
| Pressure and density reference | Initial pressure 101,325 Pa; the closed-domain gas run determines its mean pressure from the fixed mass and temperature field |
7 Numerical Methods
The flow and energy linear systems were solved with FGMRES and algebraic multigrid (AMG) preconditioners. Each linear solve used a limit of 50 iterations and a tolerance of \(10^{-3}\). Energy advection used second-order linear upwinding. Both models used uniform pseudo-time steps of 0.1 s. The Boussinesq model used a scaled-residual target of \(10^{-10}\) and a 6,000-iteration limit; the ideal-gas model used \(10^{-8}\) and 3,000 iterations. Both also used an absolute-residual indicator with a log10 threshold of \(-15\). All eight reported calculations (four meshes for each density model) reached their configured convergence criterion within 233–387 iterations. The same numerical settings were used across the mesh family.
8 Results
The inner-wall equivalent conductivity approached a stable value as the mesh was refined. The last row is a Richardson extrapolation from the three finest meshes, using order two for the inner-wall conductivity extrapolation.
| Radial × azimuthal cells | Boussinesq \(k_{\mathrm{eq}}\) | Ideal-gas \(k_{\mathrm{eq}}\) |
|---|---|---|
| 20 × 60 | 2.97421 | 2.94479 |
| 40 × 120 | 2.95096 | 2.92282 |
| 80 × 240 | 2.94760 | 2.91963 |
| 160 × 480 | 2.94757 | 2.91956 |
| Extrapolated | 2.94756 | 2.91954 |
The extrapolated Boussinesq result was about 6.8% below the interpolated experimental value of 3.161; the ideal-gas result was about 7.6% below it. The extrapolated inner-wall conductivities differed by about 0.95% between the models, less than the difference between either model and the experimental reference. Post-processing with one-sided wall temperature gradients gave an inner–outer wall heat-transfer imbalance of about 0.21% on the finest mesh.
The temperature profiles along the symmetry lines above and below the inner cylinder also tended to stabilize as the mesh was refined. On the finest mesh, the Boussinesq result differs from the experimental points extracted from the reference figure by a mean of \(-1.85\) K above and \(+1.27\) K below the cylinder. The corresponding ideal-gas differences are \(-2.17\) K and \(+1.23\) K. These point comparisons include error from digitizing the experimental markers in the source figure.






9 Conclusions and Applicable Scope
For this laminar annulus configuration, both density models approached stable equivalent conductivities as the mesh was refined. Both extrapolated values were within 8% of the interpolated experimental reference, with the Boussinesq result slightly closer. These results apply to the stated geometry, Rayleigh number, fluid properties, wall temperatures, and serial execution. Other Rayleigh numbers, transitional or turbulent natural convection, and other annulus geometries were outside the scope of this evaluation. The experimental comparison also includes the difference between the nitrogen measurements and the air simulation.
10 References
- Kuehn, T. H., and Goldstein, R. J. “An Experimental Study of Natural Convection Heat Transfer in Concentric and Eccentric Horizontal Cylindrical Annuli.” Journal of Heat Transfer 100 (1978): 635–640. doi:10.1115/1.3450869.