Conjugate Heat Transfer — Flat Plate Verification

Interface temperature and Nusselt number against the Vynnycky (1998) closed-form conjugate solution, 2D/3D and conformal/non-conformal interfaces

Wake CFD flat-plate conjugate heat-transfer results were compared with the Vynnycky analytical correlation for 2D and 3D configurations with conformal and non-conformal interfaces.

1 Run Provenance and Artifacts

Item Value
Solver DBNS
Arithmetic precision FP64

1.1 Downloadable Files

Not yet available. Standalone input decks and solver result files for this case are planned for a future release.

2 Verification Objective

Forced convection over a conducting flat plate was computed and compared with the asymptotic analytical correlation of Vynnycky, Kimura, Kanev, and Pop (1998). The calculation coupled temperature and heat flux across the fluid–solid interface. The evaluation covered:

  • interface-averaged temperature θ̄_b and Nusselt number N̄u against the analytical correlation;
  • consistency across four configurations combining 2D/3D geometry and conformal/non-conformal interface meshes.

3 Reference Solution and Data

Item Setting
Reference Vynnycky, Kimura, Kanev, and Pop (1998), closed-form asymptotic solution

4 Simulation Conditions

Item Setting
Geometry Conducting solid slab (x∈[-0.5,0.5], y∈[-0.5,0]) beneath a fluid domain (x∈[-1.0,2.0], y∈[0,1.0]); interface at y=0, |x|≤0.5
Analysis Steady, laminar, compressible DBNS with conjugate fluid-solid coupling
Re (plate-length based) 500
Pr 0.72
Conductivity ratio k̄ = k_solid/k_fluid 5
Thickness ratio λ = a/b 0.5
Freestream M = 0.1, p_∞ = 101325 Pa, T_∞ = 300 K, flow along +x
Material properties Ideal gas, γ=1.4, R=287 J/(kg·K); constant fluid viscosity 0.08171 Pa·s, fluid conductivity 113.95 W/(m·K), solid conductivity 569.75 W/(m·K)

Conformal vs. non-conformal 2D mesh: full domain and interface close-up (conformal interface: 101 matching nodes each side; non-conformal: 101 fluid vs. 67 solid nodes, GGI-interpolated)

5 Mesh

Item Setting
Mesh variants 2D and 3D (one-cell spanwise extrusion + symmetry), each with a conformal (matching interface node count) and non-conformal (mismatched, GGI-interpolated) fluid-solid interface

6 Boundary and Initial Conditions

Item Setting
Fluid inlet (INLET) Farfield; M=0.1, p=101325 Pa, T=300 K, zero angle of attack
Fluid outlet (OUTLET) Pressure outlet, back pressure 101325 Pa
Fluid top and lower boundaries outside the plate (FARFIELD, SYMMETRY_UP, SYMMETRY_DN) Symmetry conditions
Solid bottom (BOTTOM) Isothermal, T_c=330 K
Solid sides (LEFT, RIGHT) Adiabatic
Fluid–solid interface (INTERFACE) No-slip on the fluid side; coupled temperature and heat-flux continuity
Spanwise end faces in 3D Symmetry for both fluid and solid
Fluid initial field Uniform flow (uniform); M=0.1, p=101325 Pa, T=300 K, directed along +x

Fluid–solid coupling determined the interface temperature. The prescribed 330 K temperature applies to the solid bottom, separately from the coupled interface temperature.

7 Numerical Methods

Item Setting
Convective scheme SLAU
Pseudo-time integration Implicit, fixed CFL 5.0
Convergence criterion residual_reduction=8, residual_absolute=-10; maximum 50,000 iterations

8 Results

At the given conditions (Re=500, Pr=0.72, k̄=5, λ=0.5), the analytical solution gives μ = λ·Pr^(1/3)·Re^(1/2) / (1.506·k̄) ≈ 1.331, θ̄_b = 1/(1+μ) ≈ 0.429, and N̄u = (k̄/λ)·μ/(1+μ) ≈ 5.71.

Case Converged iteration θ̄_b (area-weighted) vs. analytical (0.429) N̄u vs. analytical (5.71)
2D conformal 10,637 0.4223 −1.6% 5.7738 +1.1%
2D non-conformal 9,408 0.4251 −0.9% 5.8122 +1.8%
3D conformal 13,023 0.4223 −1.6% 5.7738 +1.1%
3D non-conformal (GGI) 11,873 0.4251 −0.9% 5.8122 +1.8%

All four configurations reached the eight-order residual-reduction criterion. The mean interface-temperature differences were −1.6% to −0.9%, and the mean Nusselt-number differences were +1.1% to +1.8%. The 2D/3D results matched to four decimal places within each interface type. The conformal/non-conformal differences were 0.0028 in θ̄_b and 0.0384 in N̄u.

Coupled fluid-solid temperature field, conformal 2D case, deep-converged

The local (as opposed to area-averaged) interface temperature distribution θ_b(x) was also compared against a separate constant-heat-flux asymptotic approximation from the same reference (valid, per the reference’s own statement, only for Pr≫1):

Local interface temperature distribution θ_b(x): Wake CFD (all four discretizations) versus the constant-flux approximation evaluated at Pr=0.72

The computed local θ_b(x) distribution differed clearly from the constant-flux approximation. The local comparison evaluated an approximation for Pr≫1 at the present Pr=0.72, separately from the area-averaged correlation above.

9 Conclusions and Applicable Scope

  • The area-averaged interface temperature and Nusselt number agreed with the Vynnycky (1998) analytical correlation within 2% across the four configurations.
  • For both conformal and non-conformal interfaces, the 2D and one-layer-extruded 3D averages matched to four decimal places. The differences between interface types are reported above.
  • The local interface temperature differed from the constant-flux approximation for Pr≫1. The local comparison at Pr=0.72 was separate from verification of the area-averaged quantities.
  • The evaluation covered steady laminar forced convection over a conducting flat plate at Re=500, Pr=0.72, conductivity ratio 5, thickness ratio 0.5, and M=0.1.

10 References

  • Vynnycky, M., Kimura, S., Kanev, K., and Pop, I., “Forced Convection Heat Transfer from a Flat Plate: The Conjugate Problem,” International Journal of Heat and Mass Transfer, 41(1), 1998, pp. 45–59.