2 Verification Objective
Forced convection over a conducting flat plate was computed and compared with the asymptotic analytical correlation of Vynnycky, Kimura, Kanev, and Pop (1998). The calculation coupled temperature and heat flux across the fluid–solid interface. The evaluation covered:
- interface-averaged temperature
θ̄_band Nusselt numberN̄uagainst the analytical correlation; - consistency across four configurations combining 2D/3D geometry and conformal/non-conformal interface meshes.
3 Reference Solution and Data
| Item | Setting |
|---|---|
| Reference | Vynnycky, Kimura, Kanev, and Pop (1998), closed-form asymptotic solution |
4 Simulation Conditions
| Item | Setting |
|---|---|
| Geometry | Conducting solid slab (x∈[-0.5,0.5], y∈[-0.5,0]) beneath a fluid domain (x∈[-1.0,2.0], y∈[0,1.0]); interface at y=0, |x|≤0.5 |
| Analysis | Steady, laminar, compressible DBNS with conjugate fluid-solid coupling |
Re (plate-length based) |
500 |
Pr |
0.72 |
Conductivity ratio k̄ = k_solid/k_fluid |
5 |
Thickness ratio λ = a/b |
0.5 |
| Freestream | M = 0.1, p_∞ = 101325 Pa, T_∞ = 300 K, flow along +x |
| Material properties | Ideal gas, γ=1.4, R=287 J/(kg·K); constant fluid viscosity 0.08171 Pa·s, fluid conductivity 113.95 W/(m·K), solid conductivity 569.75 W/(m·K) |

5 Mesh
| Item | Setting |
|---|---|
| Mesh variants | 2D and 3D (one-cell spanwise extrusion + symmetry), each with a conformal (matching interface node count) and non-conformal (mismatched, GGI-interpolated) fluid-solid interface |
6 Boundary and Initial Conditions
| Item | Setting |
|---|---|
Fluid inlet (INLET) |
Farfield; M=0.1, p=101325 Pa, T=300 K, zero angle of attack |
Fluid outlet (OUTLET) |
Pressure outlet, back pressure 101325 Pa |
Fluid top and lower boundaries outside the plate (FARFIELD, SYMMETRY_UP, SYMMETRY_DN) |
Symmetry conditions |
Solid bottom (BOTTOM) |
Isothermal, T_c=330 K |
Solid sides (LEFT, RIGHT) |
Adiabatic |
Fluid–solid interface (INTERFACE) |
No-slip on the fluid side; coupled temperature and heat-flux continuity |
| Spanwise end faces in 3D | Symmetry for both fluid and solid |
| Fluid initial field | Uniform flow (uniform); M=0.1, p=101325 Pa, T=300 K, directed along +x |
Fluid–solid coupling determined the interface temperature. The prescribed 330 K temperature applies to the solid bottom, separately from the coupled interface temperature.
7 Numerical Methods
| Item | Setting |
|---|---|
| Convective scheme | SLAU |
| Pseudo-time integration | Implicit, fixed CFL 5.0 |
| Convergence criterion | residual_reduction=8, residual_absolute=-10; maximum 50,000 iterations |
8 Results
At the given conditions (Re=500, Pr=0.72, k̄=5, λ=0.5), the analytical solution gives μ = λ·Pr^(1/3)·Re^(1/2) / (1.506·k̄) ≈ 1.331, θ̄_b = 1/(1+μ) ≈ 0.429, and N̄u = (k̄/λ)·μ/(1+μ) ≈ 5.71.
| Case | Converged iteration | θ̄_b (area-weighted) |
vs. analytical (0.429) |
N̄u |
vs. analytical (5.71) |
|---|---|---|---|---|---|
| 2D conformal | 10,637 | 0.4223 | −1.6% | 5.7738 | +1.1% |
| 2D non-conformal | 9,408 | 0.4251 | −0.9% | 5.8122 | +1.8% |
| 3D conformal | 13,023 | 0.4223 | −1.6% | 5.7738 | +1.1% |
| 3D non-conformal (GGI) | 11,873 | 0.4251 | −0.9% | 5.8122 | +1.8% |
All four configurations reached the eight-order residual-reduction criterion. The mean interface-temperature differences were −1.6% to −0.9%, and the mean Nusselt-number differences were +1.1% to +1.8%. The 2D/3D results matched to four decimal places within each interface type. The conformal/non-conformal differences were 0.0028 in θ̄_b and 0.0384 in N̄u.

The local (as opposed to area-averaged) interface temperature distribution θ_b(x) was also compared against a separate constant-heat-flux asymptotic approximation from the same reference (valid, per the reference’s own statement, only for Pr≫1):

θ_b(x): Wake CFD (all four discretizations) versus the constant-flux approximation evaluated at Pr=0.72The computed local θ_b(x) distribution differed clearly from the constant-flux approximation. The local comparison evaluated an approximation for Pr≫1 at the present Pr=0.72, separately from the area-averaged correlation above.
9 Conclusions and Applicable Scope
- The area-averaged interface temperature and Nusselt number agreed with the Vynnycky (1998) analytical correlation within 2% across the four configurations.
- For both conformal and non-conformal interfaces, the 2D and one-layer-extruded 3D averages matched to four decimal places. The differences between interface types are reported above.
- The local interface temperature differed from the constant-flux approximation for
Pr≫1. The local comparison atPr=0.72was separate from verification of the area-averaged quantities. - The evaluation covered steady laminar forced convection over a conducting flat plate at
Re=500,Pr=0.72, conductivity ratio5, thickness ratio0.5, andM=0.1.
10 References
- Vynnycky, M., Kimura, S., Kanev, K., and Pop, I., “Forced Convection Heat Transfer from a Flat Plate: The Conjugate Problem,” International Journal of Heat and Mass Transfer, 41(1), 1998, pp. 45–59.