3D Supersonic Square Duct — SA-QCR2000 Secondary-Flow Validation
Confirmation that the Quadratic Constitutive Relation reproduces corner secondary flow, against the Davis-Gessner (1989) experiment and CFL3D/FUN3D reference solutions
1 Run Provenance and Artifacts
| Item | Value |
|---|---|
| Solver | DBNS |
| Compute device | GPU |
| Arithmetic precision | FP64 |
1.1 Downloadable Files
Not yet available. Standalone input decks and solver result files for this case are planned for a future release.
2 Validation Objective
Supersonic square-duct flow was computed using Wake CFD’s SA and SA-QCR2000 models to compare their predictions of corner secondary flow of the second kind. The velocity and skin-friction profiles were assessed against the Davis and Gessner (1989) experiment and the CFL3D (SA) and FUN3D (SA-QCR2000) solutions on the same grid. The reference data came from the NASA Turbulence Modeling Resource (TMR) 3D Supersonic Square Duct case.
3 Reference Solution and Data
| Item | Setting |
|---|---|
| References | Davis and Gessner (1989) experiment; CFL3D (SA) and FUN3D (SA-QCR2000), published by NASA TMR |
4 Simulation Conditions
| Item | Setting |
|---|---|
| Geometry | Experimental duct width D=25.4 mm; computational grid uses D=1 m with a Reynolds-matched reference state. Length 52D; quarter-domain with two symmetry planes and two viscous walls |
| Analysis | Steady, compressible DBNS, RANS (SA, run with and without QCR2000) |
| Inflow Mach | 3.9 (uniform inflow; boundary layer develops from the duct entrance) |
Re_D |
0.508×10⁶ |
| Computational freestream state | p=569.2 Pa, T=288.889 K, reference density 6.8441×10^-3 kg/m³ |
| Material properties | Ideal gas (γ=1.4, R=287.87 J/(kg·K)); Sutherland viscosity (μ_ref=1.716×10^-5 Pa·s, T_ref=273.15 K, S=110.4 K), Pr=0.72 |
| Evaluation stations | x/D=40, 50, in the fully turbulent region |

Velocity and skin-friction profiles were compared on the medium grid used by the reference solutions. The assessment also considered changes between the coarse and medium grids.

5 Mesh
| Item | Setting |
|---|---|
| Mesh | Unstructured hexahedral, nested two-level family used for comparison: coarse (241×41×41) and medium (481×81×81, matching the reference solutions’ grid) |
6 Boundary and Initial Conditions
| Item | Setting |
|---|---|
Inlet (QUAD_bdy 1) |
Supersonic farfield inflow; M=3.9, p=569.2 Pa, T=288.889 K, flow along +x, SA ν̃/ν=3 |
Outlet (QUAD_bdy 2) |
Pressure outlet; nominal back pressure 569.2 Pa, interior-state extrapolation for supersonic outflow |
Walls (QUAD_bdy 3, QUAD_bdy 5) |
No-slip, adiabatic walls at y=0 and z=0 |
Symmetry planes (QUAD_bdy 4, QUAD_bdy 6) |
Symmetry at y/D=0.5 and z/D=0.5 |
| Initial field | Uniform flow (uniform); M=3.9, p=569.2 Pa, T=288.889 K, directed along +x |
In the calculation, wall boundary layers developed from a uniform inlet, whereas the experiment had a facility-developed inlet boundary layer. The comparison used the stations at x/D=40, 50.
7 Numerical Methods
| Item | Setting |
|---|---|
| Convective scheme and gradients | Roe, Green–Gauss |
| Limiter | Venkat–Wang (venkat_wang), coefficient 0.05; frozen after 8,000 iterations on coarse and 16,000 on medium |
| Pseudo-time integration | Euler implicit; CFL starts at 0.5, with a 1,000-iteration ramp toward 5.0 scheduled at iteration 200 |
| Linear solver | FGMRES/DILU, tolerance 0.01; maximum 50 linear iterations on coarse, 25 on medium |
| Termination settings | Coarse: six-order residual-reduction target, maximum 40,000 iterations; medium: eight-order target, maximum 60,000 iterations |
8 Results
The coarse SA and SA-QCR2000 runs reached six-order residual reduction at iterations 12,411 and 13,685, respectively. Both medium-grid runs ended at the 60,000-iteration limit, with residual reductions of approximately 6.7 orders for SA and 7.1 orders for SA-QCR2000. Integrated CFx changed by less than 0.01% over the final 5,000 iterations.
8.1 Secondary-Flow Signature (SA vs. SA-QCR2000)
In-plane velocity magnitude (relative to centerline axial velocity u_max) at the judgment stations, medium grid:
| Model | max \|(v,w)\|/u_max |
rms |
|---|---|---|
| SA | 0.09–0.14% | 0.02–0.03% |
| SA-QCR2000 | 1.18–1.19% | 0.53% |


The maximum in-plane velocity was 0.09–0.14% of u_max for SA and 1.18–1.19% for SA-QCR2000. The SA-QCR2000 field showed inflow along the corner bisector, return flow along both walls, and a pair of counter-rotating corner vortices. Its intensity was close to the experimental scale of approximately 1%.
8.2 Comparison Against Experiment and Reference Codes (medium grid)


- Wake CFD SA and CFL3D SA agree closely — the velocity and skin-friction profiles are within the plotted resolution of each other. Both codes show the same gap against the experiment (under-predicted diagonal velocity deficit, missing skin-friction inner peak).
- Wake CFD SA-QCR2000 and FUN3D SA-QCR2000 agree closely — velocity profiles overlap; skin friction agrees in peak location and shape, with the reference computation running slightly higher (1–2%) in part of the profile. Against the experiment, SA-QCR2000 reproduces the diagonal-cut velocity deficit and the skin-friction inner peak that SA misses, and matches the experimental data closely at
x/D=40.
9 Conclusions and Applicable Scope
- SA-QCR2000 reproduced a pair of counter-rotating corner vortices. The maximum in-plane velocity on the medium grid was
1.18–1.19%of the centerline velocity, compared with0.09–0.14%for SA. - On the same medium grid as the reference solutions, Wake CFD SA gave profiles close to CFL3D SA, and Wake CFD SA-QCR2000 gave profiles close to FUN3D SA-QCR2000. SA-QCR2000 reproduced the diagonal velocity deficit and inner skin-friction peak observed in the experiment.
- From coarse to medium, the integrated SA
CFxchanged by approximately0.02%. The SA-QCR2000 secondary-flow intensity increased from approximately1.05%to1.18%, a change of about13%. The assessment of its medium-grid magnitude also considered this grid dependence and the termination states reported above. - The evaluation covered steady turbulent square-duct flow at
M=3.9andRe_D=0.508×10⁶, using uniform inflow and adiabatic no-slip walls, with comparisons atx/D=40, 50.
10 References
- Davis, D. O., and Gessner, F. B., “Further Experiments on Supersonic Turbulent Flow Development in a Square Duct,” AIAA Journal, 27(8), 1989, pp. 1023–1030, doi:10.2514/3.10216.
- Spalart, P. R., “Strategies for Turbulence Modelling and Simulations,” International Journal of Heat and Fluid Flow, 21(3), 2000, pp. 252–263.
- NASA Turbulence Modeling Resource, 3D Supersonic Square Duct Validation Case.