3D Supersonic Square Duct — SA-QCR2000 Secondary-Flow Validation

Confirmation that the Quadratic Constitutive Relation reproduces corner secondary flow, against the Davis-Gessner (1989) experiment and CFL3D/FUN3D reference solutions

Wake CFD’s SA and SA-QCR2000 models were evaluated for corner secondary flow in a supersonic square duct. Velocity and skin friction were compared with Davis and Gessner’s measurements and CFL3D and FUN3D results.

1 Run Provenance and Artifacts

Item Value
Solver DBNS
Compute device GPU
Arithmetic precision FP64

1.1 Downloadable Files

Not yet available. Standalone input decks and solver result files for this case are planned for a future release.

2 Validation Objective

Supersonic square-duct flow was computed using Wake CFD’s SA and SA-QCR2000 models to compare their predictions of corner secondary flow of the second kind. The velocity and skin-friction profiles were assessed against the Davis and Gessner (1989) experiment and the CFL3D (SA) and FUN3D (SA-QCR2000) solutions on the same grid. The reference data came from the NASA Turbulence Modeling Resource (TMR) 3D Supersonic Square Duct case.

3 Reference Solution and Data

Item Setting
References Davis and Gessner (1989) experiment; CFL3D (SA) and FUN3D (SA-QCR2000), published by NASA TMR

4 Simulation Conditions

Item Setting
Geometry Experimental duct width D=25.4 mm; computational grid uses D=1 m with a Reynolds-matched reference state. Length 52D; quarter-domain with two symmetry planes and two viscous walls
Analysis Steady, compressible DBNS, RANS (SA, run with and without QCR2000)
Inflow Mach 3.9 (uniform inflow; boundary layer develops from the duct entrance)
Re_D 0.508×10⁶
Computational freestream state p=569.2 Pa, T=288.889 K, reference density 6.8441×10^-3 kg/m³
Material properties Ideal gas (γ=1.4, R=287.87 J/(kg·K)); Sutherland viscosity (μ_ref=1.716×10^-5 Pa·s, T_ref=273.15 K, S=110.4 K), Pr=0.72
Evaluation stations x/D=40, 50, in the fully turbulent region

Medium-grid (481×81×81) mesh overview, one-quarter domain

Velocity and skin-friction profiles were compared on the medium grid used by the reference solutions. The assessment also considered changes between the coarse and medium grids.

Mach-number contours over the duct surface, SA-QCR2000, medium grid

5 Mesh

Item Setting
Mesh Unstructured hexahedral, nested two-level family used for comparison: coarse (241×41×41) and medium (481×81×81, matching the reference solutions’ grid)

6 Boundary and Initial Conditions

Item Setting
Inlet (QUAD_bdy 1) Supersonic farfield inflow; M=3.9, p=569.2 Pa, T=288.889 K, flow along +x, SA ν̃/ν=3
Outlet (QUAD_bdy 2) Pressure outlet; nominal back pressure 569.2 Pa, interior-state extrapolation for supersonic outflow
Walls (QUAD_bdy 3, QUAD_bdy 5) No-slip, adiabatic walls at y=0 and z=0
Symmetry planes (QUAD_bdy 4, QUAD_bdy 6) Symmetry at y/D=0.5 and z/D=0.5
Initial field Uniform flow (uniform); M=3.9, p=569.2 Pa, T=288.889 K, directed along +x

In the calculation, wall boundary layers developed from a uniform inlet, whereas the experiment had a facility-developed inlet boundary layer. The comparison used the stations at x/D=40, 50.

7 Numerical Methods

Item Setting
Convective scheme and gradients Roe, Green–Gauss
Limiter Venkat–Wang (venkat_wang), coefficient 0.05; frozen after 8,000 iterations on coarse and 16,000 on medium
Pseudo-time integration Euler implicit; CFL starts at 0.5, with a 1,000-iteration ramp toward 5.0 scheduled at iteration 200
Linear solver FGMRES/DILU, tolerance 0.01; maximum 50 linear iterations on coarse, 25 on medium
Termination settings Coarse: six-order residual-reduction target, maximum 40,000 iterations; medium: eight-order target, maximum 60,000 iterations

8 Results

The coarse SA and SA-QCR2000 runs reached six-order residual reduction at iterations 12,411 and 13,685, respectively. Both medium-grid runs ended at the 60,000-iteration limit, with residual reductions of approximately 6.7 orders for SA and 7.1 orders for SA-QCR2000. Integrated CFx changed by less than 0.01% over the final 5,000 iterations.

8.1 Secondary-Flow Signature (SA vs. SA-QCR2000)

In-plane velocity magnitude (relative to centerline axial velocity u_max) at the judgment stations, medium grid:

Model max \|(v,w)\|/u_max rms
SA 0.09–0.14% 0.02–0.03%
SA-QCR2000 1.18–1.19% 0.53%

In-plane velocity vectors and magnitude at x/D=50, SA versus SA-QCR2000 (corner vortex pair), medium grid

In-plane velocity vectors and magnitude at x/D=50, SA-QCR2000, medium grid

The maximum in-plane velocity was 0.09–0.14% of u_max for SA and 1.18–1.19% for SA-QCR2000. The SA-QCR2000 field showed inflow along the corner bisector, return flow along both walls, and a pair of counter-rotating corner vortices. Its intensity was close to the experimental scale of approximately 1%.

8.2 Comparison Against Experiment and Reference Codes (medium grid)

Velocity profile comparison at x/D=50: Wake CFD SA and SA-QCR2000 versus experiment, CFL3D SA, and FUN3D SA-QCR2000

Skin-friction comparison at x/D=50: Wake CFD SA and SA-QCR2000 versus experiment, CFL3D SA, and FUN3D SA-QCR2000
  • Wake CFD SA and CFL3D SA agree closely — the velocity and skin-friction profiles are within the plotted resolution of each other. Both codes show the same gap against the experiment (under-predicted diagonal velocity deficit, missing skin-friction inner peak).
  • Wake CFD SA-QCR2000 and FUN3D SA-QCR2000 agree closely — velocity profiles overlap; skin friction agrees in peak location and shape, with the reference computation running slightly higher (1–2%) in part of the profile. Against the experiment, SA-QCR2000 reproduces the diagonal-cut velocity deficit and the skin-friction inner peak that SA misses, and matches the experimental data closely at x/D=40.

9 Conclusions and Applicable Scope

  • SA-QCR2000 reproduced a pair of counter-rotating corner vortices. The maximum in-plane velocity on the medium grid was 1.18–1.19% of the centerline velocity, compared with 0.09–0.14% for SA.
  • On the same medium grid as the reference solutions, Wake CFD SA gave profiles close to CFL3D SA, and Wake CFD SA-QCR2000 gave profiles close to FUN3D SA-QCR2000. SA-QCR2000 reproduced the diagonal velocity deficit and inner skin-friction peak observed in the experiment.
  • From coarse to medium, the integrated SA CFx changed by approximately 0.02%. The SA-QCR2000 secondary-flow intensity increased from approximately 1.05% to 1.18%, a change of about 13%. The assessment of its medium-grid magnitude also considered this grid dependence and the termination states reported above.
  • The evaluation covered steady turbulent square-duct flow at M=3.9 and Re_D=0.508×10⁶, using uniform inflow and adiabatic no-slip walls, with comparisons at x/D=40, 50.

10 References

  • Davis, D. O., and Gessner, F. B., “Further Experiments on Supersonic Turbulent Flow Development in a Square Duct,” AIAA Journal, 27(8), 1989, pp. 1023–1030, doi:10.2514/3.10216.
  • Spalart, P. R., “Strategies for Turbulence Modelling and Simulations,” International Journal of Heat and Fluid Flow, 21(3), 2000, pp. 252–263.
  • NASA Turbulence Modeling Resource, 3D Supersonic Square Duct Validation Case.